Custom Oscillator Package Options
| Specification |
Performance |
Package |
| Frequency |
1 Hz to 40 Mhz
4 MHz to 40 MHz
250 kHz to 40 MHz |
A, B, B1, D, D1, F
E, E1, G
C, C1, H, H1 |
| Voltage |
+5.0 to +15.0 volts |
A, B, B1, C, C1, D, D1, E, E1, F,
G, H, H1 |
HCMOS & LSTTL Output
Waveform
Logic Levels
Fan Out
Mark Space Ratio
Fall & Rise Ratio |
Squarewave HCMOS/TTL compatible
Low <+0.4V High >+4.5V
30pF or 5 TTL Gates
55:45 at 45:55 at +2.5V
5ns maximum |
A, B, B1, C, C1, D, D1, E, E1, F, G, H, H1 |
TTL Output
Waveform
Logic Levels
Fan Out
Mark Space Ratio |
TTL Compatible
Low <+0.4V High >+2.4V
3 TTL Gates
65:35 at 35:65 at +1.4V |
A, B, D, D1, F, G |
Sinewave Output
Waveform
Output Level
Load Impedance |
A.C. coupled sinewave
1 volt peak to peak minimum
1 kW in parallel with 12pF |
A, B, D, D1, F, G |
Adjustment Method
External Potentiometer
Internal Trimmer
External Voltage |
±5.0ppm min. via an external 10kW pot.
±5.0ppm min. via an internal trimmer cap.
±100ppm min. via a control voltage of +0.5 to
+4.5V (up to ±250ppm is available upon
request) |
A, B, C, D
B1, C1, D1, E1, F, G, H1
E, H |
Stability
With Time
With Voltage
With Load
With Time
With Voltage
With Load
With Temperature |
±1.0ppm per year max. at +25°C
±0.3ppm for a ±5% change in supply voltage
±0.3ppm for a ±10% change in load impedance
±2.0ppm per year max. at +25°C
±3.0ppm for a ±5% change in supply voltage
±0.5ppm for a ±10% change in load impedance
See temperature tables |
E, E1, H, H1 |
Customised Oscillators
These types of customised oscillators represent only our most popular units from a much
wider range. As with all frequency control products the majority of users require unique
specifications for many of their products. Hy-Q specialise in custom designs and
hence any criteria which is not met from our standard range can usually be incorporated
into a custom design. Whatever the requirement, even if it seems well outside the range of
the standard products on offer, our technical staff are always available to discuss your
application and decide upon the device specifications that best suit your needs.
| General
Note |
| Ageing: |
Ageing specifications are based on
experience of our previously manufactured devices and are not explicitly guaranteed. |